W42655   Closed

05/15/2026, 02:00 pm   
Onsite
Normal
UOG0.4004: UOG PO251263 Verkada Installation 2025
UOG PO251263 Verkada Installation 2025 [TOTAL ANNUAL HOURS: 80]
54
2
Sean Bacani
No

Work Requested

- Installation of the 3rd camera in the SBPA 2nd Floor Copier Room. - Installation of the environmental sensor at Café Sirena. - Troubleshooting of the fisheye camera in the SBPA Atrium.
Work Requested by: Andrew Guihama

Items Dropped Off 0

Item Serial Number Notes

Work Completed 1

Summary of Tasks

- Kevin advised they are missing the mounting plate for the sensor, unable to install sensor. Arty advised someone from their department was testing it last time and he will ask them. - Troubleshooted fisheye camera for SBPA Atrium, camera is not able to power on. - Verified cable is able to supply power. - Tested another camera, powers on. Verified cable has no issues. - Checked the camera specs, it needs POE+ rating for the switch. Current switch onsite only has POE and has a max of 30W, the camera needs 37W higher or POE+ switch. - Tested using a POE+ injector, camera is still unable to turn on. Tested camera using a short cable near the switch with the POE+ injector, same issues. - Possible fault in fisheye camera hardware itself. - Advised Arty that the switch does not provide enough power and is not rated for POE+. - Investigated ways to install the 3rd camera for the SBPA Copier Room. Will install a switch alongside the AC12 to facilitate both camera and the access control. - Advised Arty for service to continue on Monday to install the switch and camera for the 2nd Floor SBPA Copier room.
Work Completed Technician Check-in Check-out Actual Hrs
1 - Kevin advised they are missing the mounting plate for the sensor, unable to install sensor. Arty advised someone from their department was testing it last time and he will ask them. - Troubleshooted fisheye camera for SBPA Atrium, camera is not able to power on. - Verified cable is able to supply power. - Tested another camera, powers on. Verified cable has no issues. - Checked the camera specs, it needs POE+ rating for the switch. Current switch onsite only has POE and has a max of 30W, the camera needs 37W higher or POE+ switch. - Tested using a POE+ injector, camera is still unable to turn on. Tested camera using a short cable near the switch with the POE+ injector, same issues. - Possible fault in fisheye camera hardware itself. - Advised Arty that the switch does not provide enough power and is not rated for POE+. - Investigated ways to install the 3rd camera for the SBPA Copier Room. Will install a switch alongside the AC12 to facilitate both camera and the access control. - Advised Arty for service to continue on Monday to install the switch and camera for the 2nd Floor SBPA Copier room. Sean Bacani
05/15/2026 01:50 pm 05/15/2026 04:00 pm 02:10

Parts and Materials 0

Item Serial Number Condition Qty Price Amount
TOTAL ($)   0.00

Comments For Internal Use only. 14

Date/Time Comment Tech
05/18/2026 05:17 pm Updated status to Closed Jessica L.
05/17/2026 06:06 pm Updated status to Submitted for Invoicing Chu H.
05/17/2026 06:06 pm Approved. Chu H.
05/15/2026 04:46 pm No Signature: - UOG Verkada Project Sean B.
05/15/2026 04:46 pm Updated status to Pending Approval Sean B.
05/15/2026 04:46 pm Service Completed Sean B.
05/15/2026 04:46 pm Check-out 05/15/2026 04:00 pm Sean B.
05/15/2026 04:46 pm Work Order Tasks Added Sean B.
05/15/2026 04:46 pm Updated status to Service Completed Sean B.
05/15/2026 04:43 pm Arrived 05/15/2026 02:15 pm Sean B.
05/15/2026 04:42 pm Check-in 05/15/2026 01:50 pm Sean B.
05/15/2026 04:42 pm Updated status to Scheduled Sean B.
05/15/2026 04:42 pm Assigned: Sean Bacani Sean B.
05/15/2026 04:42 pm Created workorder. Sean B.

Attachments 1

Filename
W42655